| Source Files Required |
.RPT, or .VHD & .XRF |
| Design Software |
Cypress Warp5 Software |
| Supported Families |
Flash370i, Ultra37000, Delta39K |
How to obtain a VHD & XRF
- From the Galaxy main menu, select PROJECT [Compiler
Options].
- Select SIMULATION [Timing Model] type VIEWSIM.
- Compile Project. Warp! Software then compiles the
design and creates a VHD subdirectory. This subdirectory
can be found in the Project directory folder.
- Using VHD2FS*, translate the Viewsim .VHD file into
the appropriate VHD & XRF files. Syntax from DOS
prompt: c/> vhd2fs -i <input file> -o <output
file>
- VHD & XRF files are ready to work with FS-ATG.
* If you do not have the VHD2FS translator, please
contact Flynn Systems technical support to request
it
How to obtain an RPT
- From the Galaxy main menu, select the TOP-LEVEL design
file. In the Compile box, click on SELECTED.
- Warp! Software then compiles the design and generates
an .RPT file.
- Change the file extension from .RPT to .RP before
you run FS-ATG. FS-ATG recognizes only files with .RP
extensions as valid Cypress source files. FS-ATG reserves
the .RPT extension for FS-ATG reports, and would overwrite
.RPT files with the same name in that directory.
|
|