| Source
Files Required |
EDO |
| Design
Software |
QuickLogic
SpDE Software |
| Supported
Families |
pASIC1, pASIC2, pASIC3 |
How to create an EDO file for QuickLogic devices
The .EDO file is a flattened
edif netlist file.
- From the SpDE Tools menu
select OPTIONS.
Select the BACK ANNOTATION tab, then in the simulator
window select LMCEDIF and click OK..(For
older SpDE versions, go to the File menu. Select EXPORT
LMCEDIF. Select RUN.)
- From the Tools menu, select
Run Selected Tools.This executes the Place and Route
sequence.
- The resultant .EDO file
will be ready to run with FS-ATG.
|